FC400-CCL-FA

FC400-CCL-FA

Category: Force Indicator

Specifications
Details

 

 

 

Product outline

A measurement system can be configured easily using CC-Link network.
It has displayable graph in the pc software, and setup can be done easily.
 

High sampling rate & resolution

High-Speed A/D conversion and powerful digital processing capability of 2400 times/sec.. High display resolution of 1/100000 (max).

Measurement can be performed quickly and precisely due to high speed A/D conversion.
 

Application software for USB interface

With communication through USB interface, logging, graph, display, setting parameters, and calibration can be done.

High performance filter & Auto filter adjustment

With combination of low pass filter (0.1 to 600Hz) which corresponds to various vibration and moving average filter (OFF, 2 to 999) that is effective for periodic vibration, automatic searching for optimal value with accuracy and stability can be achieved. (You can manually adjust settings too).

Lightweight and compact body to fit into limited space in a control panel

Light weight & compact body for 35mm DIN rail mount
Dimensions: 34(W)×88(H)×91(D)mm (Projections excluded)
Weight: Approx. 230g

 

Various interfaces

 

Load cell signal level display (-3.9mV/V to 3.9mV/V)

The output signal level of load cell can be displayed in mV/V for monitor purpose.
Malfunction indicator or faulty sensor can be differentiated easily.

6 digit display

24 bit A/D convertor enables 6 digit display.

Equivalent input calibration

FA
Theoretical calibration can be performed easily by registering the capacity and rated output of load cells.

Digital peak hold, Hi & Lo judgement

It can quickly capture any changes in high-speed phenomenon, and perform OK / NG judgement.

 

Specifications

Analog section
Excitation voltage DC5V±5% Output current: 90mA
DC2.5V±5% Output current: 45mA
Ratiometric method (Up to 6 350Ω load cells can be connected in parallel)
Signal input range -3.9 to 3.9mV/V
Signal input range Automatic adjustment by digital processing -3.0 ~ 3.0mV/V
Span adjustment range Automatic adjustment by digital processing 0.01 ~ 3.8mV/V
Min. input sensitivity 0.15μV/count
Accuracy Non-linearity: within 0.01%FS
Zero drift: 0.0002%FS/℃ Typ
Gain drift: 1ppm/℃ Typ
Filter Digital low-pass filter: 0.1 to 600 Hz
Moving average filter: OFF, 2 to 999 times
A/D converter Speed: 2400 times/sec.
Resolution: 24bit binary
 
Display section
Display unit Character height 8mm, Numerical display by 7-segment green LED
Display value Up to 6 digits
Display frequency Selectable from 1,3, 6, 13, 25 times/sec.
Status display RUN, SD, RD, ERR
 
Hold functions
Hold Sample,Peak,bottom,peak & bottom,average
 
External signal
Output signal (5) Transistor’s open collector output
Vceo=30V, Ic=50mA
Input signal (3) Selectable/configurable
Input is ON when shorted to COM terminal by contact (relay switch, etc.) or non contact (transistor, open collector, etc.).
* DC24V external power supply is required.
 
Interface
USB USB interface
CCL CC-Link interface
SIF SI/F 2-wire type serial interface
 
General performance
Power supply voltage DC24V (±15%)
Power consumption 4W typ
Operating conditions Temperature: Operating temperature range: -10℃ to +50℃, Storage temperature range: -20℃ to +85℃
Humidity: 85%RH or less (non-condensing)
Dimensions 34(W)×88(H)×91(D)mm (Projections excluded)
Weight Approx. 210g
CE marking certification EMC Directives EN61326-1
 
Attachments
Jumper cable 2
Mini driver 1
Various I/O connector 2
Quick manual 2
CC-Link connector 1
 

Download

Product catalogue(PDF)
FC400-FA catalogue(1 MB)


View more about FC400-CCL-FA on main site