Details
F820
Product outline
Weighing process can be visualized and configured in shorter time while keeping the top-class accuracy.
F820 is a weighing indicator designed for industrial weighing system.
F820 has high technical specifications, equipped with various functions like high-precision amplifier with ultra-low drift, high-speed sampling, weighing sequential control functions, control I/O useful for automated weighing machines, and so on.
With using special PC software, setting of the controller can be performed while monitoring the process in curve/waveform; thus, the time required for initial setup can be greatly saved.
Visualize the weighing process!
Visualization of weighing process
Fluctuations of weight can be displayed and monitored in curves. Since waveform and I/O status can be monitored at the same time, you can find out the cycle time and check weight fluctuations when SP1, 2, CMP signal turns ON/OFF.
Enlarged waveform display
With the enlarged view, you can check if weight readings is stable enough and if Set Points and the sampling rate are set properly.
Filter effect
Edit/save settings
It is convenient to save the settings for backup and export it to other units.
Statistics
Logging
A maximum of 72 hours data recording
Features
High-performance filters to attenuate vibration
High-speed sampling & high-resolution display
Ultra-low drift
Store 100 sets (codes) of settings
Measurement sequence function
■Feed and discharge gate control
F820 has sequence control functions useful for direct control of feed or discharge gate like auto feed adjustment in case the total weight is under the target weight.
■Twin net weigher mode
F820 is equipped with functions useful for twin net weigher (bagging machines) such as ''clamp'' signal output, alternative discharge and so on.
Example applications
Specifications
Analog section | |
Excitation voltage |
5 Vdc±5% Output current: within 90mA Ratiometric method (Up to 6 load cells at 350Ω can be connected in parallel.) |
---|---|
Signal input range | -0.5 to 3.0mV/V |
Zero adjustment range | -0.2 to 2.0mV/V (automatic adjustment by digital computation) |
Gain adjustment range | 0.3 to 3.0mV/V (automatic adjustment by digital computation) |
Minimum input sensitivity | 0.15μV/count |
Accuracy |
Non-linearity:within 0.01%/FS Zero drift:0.025μV/℃RTI Typ Gain drift:1ppm/℃ Typ |
A/D converter |
Speed:1200, 300 times/sec. (selectable) Resolution: 24bit (binary) |
Min. display resolution | 1/10000 |
Theoretical calibration |
equivalent input calibration (accuracy when theoretical calibration is performed at ambient: 1/1,000) |
Filter | |
Low-pass filter |
When A/D conversion rate is 1200 times/sec: 6, 8, 10, 12, 16, or 20Hz (selectable) When A/D conversion rate is 300 times/sec: 1.5, 2, 2.5, 3, 4, 5Hz (selectable) |
---|---|
Moving average filter | 1 to 512 times |
Display section | |
Display unit |
Main display: numerical display (7-digit) with a character height of 18 mm by fluorescent display tube Code (blend):Character height 8mm, numerical display by 7-segment green LED (2-digit) |
---|---|
Weight display | 5-digits (signs: minus sign on the highest numerical digit) |
Display frequency | 1, 2, 5, 10 and 20 times/sec (selectable) |
Scale capacity | 5-digit numerical values |
Minimum scale division/increment | 1 to 50(selectable) |
Unit of measurement | NONE, g, kg, t, or lb (selectable) |
Decimal place | 0, 0.0, 0.00, or 0.000 (selectable) |
Over scale display |
LOAD (A/D converter input over), OFL1; (Net weight > Net over set value) , OFL2: (Gross weight >Capacity +9 scale divisions), OFL3; (Gross weight > Gross over set value) |
Center zero | display true zero point or the center of each value |
Status display |
CLAMP, SP3, SP2, SP1, HOLD, COMPL., ZT, ZALM, STAB, TARE, NET, GROSS, NZ, D.CHG, HI, GO, LO, HI LIM, LO LIM, LOCK |
Setting section | |
Setting method |
Can edited with using membrane switch. Setting can be performed by external devices as well via USB, RS-232C and RS-485 interface and so on. |
---|---|
Setting value memory |
Parameter, calibration and part of other settings are stored on NOV.RAM (non-volatile memory), and all other settings are stored on F.RAM (another non-volatile memory). |
Setting value protection | Overwrite protection by ''LOCK'' switch |
Setting items | Upper Limit / Lower Limit / Near Zero / Set Point 1 / Set Point 2 / Compensation / Over / Under / Final / Comparison Inhibit Time / Judging Time / Complete Output Time / Compensation Feeding Time / Auto Free Fall Compensation Regulation / Weighing Function 1 / Weighing Function 2 / Tare Setting / Tare Display / Digital Low Pass Filter / Moving Average Filter / Sample Speed / Motion Detection (Period-Range) / Zero Tracking (Period) / Zero Tracking (Range) / Weighing Function 3 / Key Invalid ・ Lock / Error Output Selection / Password / Bag Clamp Output Time/ Discharging Time / Weighing Start Time / AZ Times / Judging Times / Sequence Mode 1 / Sequence Mode 2 / Extended Function Selection 1 / Extended Function Selection 2 / I/O Input Check / I/O Output Check/ BCD Input Check / BCD Output Check / RS-485 Check / Balance Weight Value / Capacity / Min Scale Division / DZ Regulation Value / Display Selection / Gravitational Acceleration / Net Over / Gross Over / RS-485 I/F Setting / RS-485 Communication Type / RS-485 ID / RS-232C I/F Setting / RS-232C Communication Type / D/A Output Mode / D/A Zero Output Weight / D/A Full Scale Value / BCD Data Update Rate / Zero Calibration / Span Calibration / Equivalent Calibration / Output Monitor Display / Option Display |
External signal | |
External output (16 points) |
Transistor open collector output. Isolation : photo coupler, Rated voltage : 30V, Maximum current : 120mA |
---|---|
External intput(22 points) |
The signal can be outputted by making short-circuit between input and common terminal. Isolation : photo coupler |
Interface | |
USB | USB interface |
---|---|
SIF | 2-wire serial interface |
232 | RS-232C communication interface (option) |
BCO | BCD parallel data output interface (option) |
DAC | D/A converter interface (option) |
485 | RS-485 communication interface (option) |
There is a option board slot only for RS-232C. Another option interface (only one option) can be installed as well. |
General performance | |
Operating voltage | AC100 to 240V(+10% -15%)[50/60Hz] |
---|---|
Rush current |
2A, 1msec:AC100V average load condition (cold start at room temperature) 4A, 1msec:AC200V average load condition (cold start at room temperature) |
Power consumption | approx.18W |
Operating conditions |
Operation temperature range:-10 to 40℃ Storage temperature range:-20 to +85℃ Humidity: 85%RH or less (non-condensing) |
Dimension |
192(W)×96(H)×145(D)mm (Projections excluded) Panel cutout size: 186(W)×92(H)mm |
Weight | approx. 1.7kg |
Attachments | |
AC power cable (voltage resistance:125 Vac ) (2m) ×1 | |
Load cell connector (JR connector) ×1 | |
Connector rubber for load cells ×1 | |
57 series connector for external input/output ×1 | |
Mini screwdriver ×1 | |
Operation manual ×1 | |
BCD output connector (when BCO option is installed) ×1 | |
D/A converter connector (when DAC option is installed) ×1 | |
RS-485 connector (when 485 option is installed) ×1 |
Optional accessories | |
CAAC3P-P2 | AC power cable 2m |
---|---|
CAAC3P-CEE7/7-P1.5 | AC power cable (voltage resistance: 250 Vac) 1.5m |
CN3P-2P | 3P-2P converter plug for AC input cord |
CA4131 | (6-wired)cable with JR connector at one end 3m |
CA4230 | JR-PRC (6-wired)conversion relay cable 0.3m |
CA4311 | JR-PRC (6-wired)conversion relay cable (4-wired to 6-wired)(for 520A use)1m |
CN10 | Loadcell connector (JR connector) |
CN21 | BCD output connector |
CN22 | 57 series 50p connector for external input/output |
CN34 | D-Sub 9p connector for RS-232C |
CN70 | D/A converter connector |
View more about F820 on main site