Details
FC400-CCL
Product outline
Equipped as standard with CC-Link interface!!
Light & compact body for DIN rail mounting.
FC400-CCL is a weighing indicator equipped as standard with CC-Link interface. It is ideal for a variety of weighing applications like hopper scales, bagging machines, and level meters.
Network with multiple units can be configured easily.
Lightweight and compact body to fit into limited space in a control panel
DIN-rail mountable
Dimensions: 34(W)×88(H)×91(D)mm (Projections excluded)
Weight: Approx. 210g
Various interfaces
Equipped with CC-link, RS-485, and USB interface!
High sampling rate & resolution
High-Speed A/D conversion and powerful digital processing capability of 1200 times/sec..
High display resolution of 1/100000 (max).
Measurement can be performed quickly and precisely due to high speed A/D conversion.
Various functions useful for automated weighing systems
■ High performance filter
As it is resistant to vibration, measurement can be performed quickly and precisely.
■ Equivalent input calibration
Theoretical calibration can be performed easily by registering the capacity and rated output of load cells.
■ Multipoint calibration (linearization)
Three additional points can be defined in the middle between zero and span for better linearity.
■ Basic weighing process control function
Sequential control can be performed without connecting external PLC etc.
Specifications
Analog|Display|External signal|Interface|General specification|Attachment
Analog | |
Excitation voltage |
DC5V±5% Output current: 90mA Ratiometric method (Up to 6 350Ω load cells can be connected in parallel) |
---|---|
Signal input range | -2.5 to 5.1mV/V |
Zero adjustment range | Automatic adjustment by digital processing -0.5 to 2.0mV/V |
Span adjustment range |
Automatic adjustment by digital processing 0.02 to 3.0mV/V |
Gain correction | Up to three point multi-point calibration is possible using linearization function |
Min. input sensitivity | 0.15μV/count |
Accuracy |
Non-linearity: within 0.01%FS Zero drift: 0.0002%FS/℃ Typ Gain drift: 1ppm/℃ Typ |
Filter |
Digital low-pass filter: 0.1 to 300 Hz Moving average filter: OFF, 2 to 512 times |
A/D converter |
Speed: 1200 times/sec. Resolution: 24bit binary |
Display | |
Display unit | Character height 8mm, Numerical display by 7-segment green LED |
---|---|
Display value | Up to 6 digits |
Display frequency | Selectable from 3, 6, 13, 25 times/sec. |
Status display | RUN, SD, RD, ERR |
External signal | |
Output signal (5 points) |
Selectable/configurable Transistor’s open collector output Vceo=30V, Ic=50mA |
---|---|
Input signal (3 points) |
Selectable/configurable Input is ON when shorted to COM terminal by contact (relay switch, etc.) or non contact (transistor, open collector, etc.). * DC24V external power supply is required. |
Interface | |
USB | USB interface |
---|---|
485 | RS-485 interface (Selectable from Modbus-RTU or UNI-Format) |
CCL | CC-Link interface |
General specification | |
Power supply voltage | DC24V (±15%) |
---|---|
Power consumption | 3W typ |
Operating conditions |
Temperature: Operating temperature range: -10℃ to +50℃, torage temperature range: -20℃ to +85℃ Humidity: 85%RH or less (non-condensing) |
Dimensions | 34(W)×88(H)×91(D) mm (Projections excluded) |
Weight | Approx. 210g |
Attachment | |
Jumper cable | 2 |
---|---|
Mini driver | 1 |
CC-Link connector | 1 |
Various I/O connector | 2 |
Quick manual | 2 |