Details
*CE-compliant model: UNCLB-500N, 1KN, 2KN
Product outline
Compact and lightweight easy-to-use load cell for both tension and compression applications.● Capacity 500 N/ 1 kN/ 2 kN/ 5 kN
● Construction material: Stainless steel
● Compact and lightweight easy-to-use load cell for both tension and compression applications
Specifications
Model | UNCLB- 500N |
UNCLB- 1KN |
UNCLB- 2KN |
UNCLB- 5KN |
---|---|---|---|---|
Rated capacity | 500 N | 1 kN | 2 kN | 5 kN |
Rated output | Approx. 0.5 mV/V | Approx. 1 mV/V | Approx. 1.5 mV/V | Approx. 2 mV/V |
Safe overload | 120% R.C. | 150% R.C. | ||
Zero balance | ±10% R.O. | |||
Non-linearity | 0.5% or less R.O. | 0.15% or less R.O. |
||
Hysteresis | 0.5% or less R.O. | 0.15% or less R.O. |
||
Repeatability | 0.3% or less R.O. | 0.1% or less R.O. |
||
Compensated temperature range |
-10 to +60℃ | |||
Safe temperature range |
-20 to +70℃ | |||
Recommended excitation voltage |
0.5% R.O./10℃ or below | |||
Temperature effect on span | 0.5% R.O./10℃ or below | |||
Input resistance | Approx. 350 Ω | |||
Maximum excitation voltage | Approx. 350 Ω | |||
Recommended excitation voltage |
2.5 V | 10 V | ||
Maximum excitation voltage | 6 V | 15 V | ||
Insulation resistance(DC 50 V) |
1000 MΩ or more | |||
Cable | φ3 4-conductor shield cable 3 m. Cable end: 5 wires |
φ6 4-conductor shield cable 5 m. Cable end: 5 wires. |
||
Cable color code | +EXC: Red +SIG: White -EXC: Blue -SIG: Black SHIELD: Shielded wire (500N, 1kN, 2kN) Yellow (5kN) |
|||
Load cell material | Stainless steel | |||
Deflection at rated | 500N:0.01 mm 1KN:0.02 mm 2KN:0.03 mm 5KN:0.06 mm |
|||
Natural frequency | 500N:16 kHz 1KN:16 kHz 2KN:19 kHz 5KN:10 kHz |
|||
Weight | 500N:85 g 1KN:85 g 2KN:85 g 5KN:500 g |
|||
RoHS directives* | 2011/65/EU (EU)2015/863 |
*CE-compliant model: UNCLB-500N, 1KN, 2KN
External dimension
Download
View more about UNCLB on main site